Menu
Your Cart

KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω

KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω
KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω
New Hot Free
KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω
KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω
KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω
  • Stock: In Stock
  • Model: KEW-4200 Kyoritsu
RS0
Ex Tax: RS0

KEW-4200 Kyoritsu Digital Earth Clamp Tester 0.05 - 1500Ω

Features:

• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.

(The Multiple Earthing System.)

• True RMS

Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A

• Noise Check Function

A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.

• Memory function

Save and display up to 100 measurement data.

• Data hold function / Buzzer function / back light function

• Compliant with Safety Standards of IEC 61010-1: CAT IV 300V Pollution degree2

Note:

A single earthing cannot be measured. (Only for Multiple Earthing System)

 

Specification:

Earth resistance Auto range

20.00/200.0/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)*
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)

AC current (50Hz/60Hz) Auto range

Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)

Operating indication

Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation

Over-range indication

"OL"is displayed when input exceeds the upper limit of a measuring range

Response time

Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)

Sample rate

Approx. 1 times per second

Current consumption

Approx. 50mA (max.100mA)

Measurement time

Approx.12 hours (when R6 is used)
Approx.24 hours (when LR6 is used)

Auto power-off

Turns power off about 10 minutes after the last button operation.

Conductor size

Approx. Ø32mm

Applicable standards

IEC 61010-1 CAT 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)

Power source

DC6V : R6(size AA manganese battery) x 4
or LR6 (size AA alkaline battery) x 4

Dimensions

246(L)×120(W)×54(D)mm

Weight

Approx. 780g (including batteries)

Included Accessories

R6 x 4, Instruction manual
8304 (Resister for operation check)
9166 (Carrying case[Hard])